==Purpose==
==Purpose==
 
Human Reliability Analysis aims to identify ways in which plant operators can intervene in the success or failure of the plant functions and systems in response to an initiating event, given the procedures for the specific plant. As it relates to advanced reactors, HRA will be a crucial element not only once a plant is operational, but also in the design and licensing phase.


==Scope==
==Scope==
 
Human Reliability Analysis for advanced reactors will cover operator actions that result in plant success as well as undesired end states related to human error. Since procedures for advanced reactors can vary widely between different designs and will be vastly different compared to water reactor procedures, the associated operator actions will likely have high variability which will need to be addressed.


==HRA==
==HRA==
Human Reliability Assessment (HRA) is required as part of the final safety analysis report (FSAR) for any licensing application using any of the potential licensing pathways.
Human Reliability Assessment (HRA) is required as part of the final safety analysis report (FSAR) for any licensing application using any of the potential licensing pathways.
Hamza and Diaconeasa introduced a framework for incorporating HRA in the early stages of design either at the pre-conceptual or conceptual design phase to develop significant operator actions early, thereby meeting the needs for ARs in their current stage.  The PRA Standard for Advanced Non-LWR Nuclear Power Plants [[References| [6]]] specifies technical requirements for the 18 elements needed to create a full-scope PRA, with two PRA Capability Categories, CC-I and CC-II, based on plant-, site-, or design-specific models. Human actions are incorporated into all 18 PRA elements, with one specific element responsible for HRA, which should be included in both capability categories to ensure the identification of risk significant events. In stakeholder interviews it was determined that a there was particular concern for the development of operator actions in response to multi-day issues and for errors of commission in relation to HRA as these may not be the dominant sources of human error for current LWRs, but could become dominant for ARs.  Roadmap actions supported emphasizing the importance of EoCs as a source of human error for ARs:
Hamza and Diaconeasa introduced a framework for incorporating HRA in the early stages of design either at the pre-conceptual or conceptual design phase to develop significant operator actions early, thereby meeting the needs for advanced reactors in their current stage [[References| [30]]].  The PRA Standard for Advanced Non-LWR Nuclear (NLWR) Power Plants (not cooled by water) [[References| [6]]] specifies high-level and supporting technical requirements for 18 technical elements needed to create a full-scope PRA. Examples are Plant Operating States, Initiating Events Analysis, Event Sequences Analysis, Systems Analysis, and some less familiar ones such as Mechanistic Source Term Analysis, Radiogical Consequence Analysis and Risk Integration. Like the ASME/ANS Level 1 PRA Standard, the NLWR Standard includes two PRA Capability Categories, CC-I and CC-II. Human actions are incorporated throughout the standard. In stakeholder interviews it was determined that a there was particular concern for the development of operator actions in response to issues that cover multiple operator shifts and for errors of commission in relation to HRA as these may not be the dominant sources of human error for current water reactors, but could become dominant for advanced reactors.  Research Roadmap (EPRI [https://www.epri.com/research/products/000000003002026495 3002026495]) actions that support emphasizing the importance of EoCs as a source of human error for advanced reactors:
*Develop Enhancements to Licensing Process
*Develop Enhancements to Licensing Process
*Develop Industry Recommendations for Regulatory (NRC / CNSC) Guidance on Operator Staffing
*Develop Industry Recommendations for Regulatory (NRC / CNSC) Guidance on Operator Staffing


A higher level of detail for these actions can be found in the roadmap along with Table 3-2 which summarizes the methods to assess HRA’s impact on AR safety.
A higher level of detail for these actions can be found in the [https://www.epri.com/research/products/000000003002026495 report] along with Table 3-2 which summarizes the methods to assess HRA’s impact on advanced reactor safety.
 
==EPRI Activities==

Latest revision as of 00:10, 30 July 2026

Purpose

Human Reliability Analysis aims to identify ways in which plant operators can intervene in the success or failure of the plant functions and systems in response to an initiating event, given the procedures for the specific plant. As it relates to advanced reactors, HRA will be a crucial element not only once a plant is operational, but also in the design and licensing phase.

Scope

Human Reliability Analysis for advanced reactors will cover operator actions that result in plant success as well as undesired end states related to human error. Since procedures for advanced reactors can vary widely between different designs and will be vastly different compared to water reactor procedures, the associated operator actions will likely have high variability which will need to be addressed.

HRA

Human Reliability Assessment (HRA) is required as part of the final safety analysis report (FSAR) for any licensing application using any of the potential licensing pathways. Hamza and Diaconeasa introduced a framework for incorporating HRA in the early stages of design either at the pre-conceptual or conceptual design phase to develop significant operator actions early, thereby meeting the needs for advanced reactors in their current stage [30]. The PRA Standard for Advanced Non-LWR Nuclear (NLWR) Power Plants (not cooled by water) [6] specifies high-level and supporting technical requirements for 18 technical elements needed to create a full-scope PRA. Examples are Plant Operating States, Initiating Events Analysis, Event Sequences Analysis, Systems Analysis, and some less familiar ones such as Mechanistic Source Term Analysis, Radiogical Consequence Analysis and Risk Integration. Like the ASME/ANS Level 1 PRA Standard, the NLWR Standard includes two PRA Capability Categories, CC-I and CC-II. Human actions are incorporated throughout the standard. In stakeholder interviews it was determined that a there was particular concern for the development of operator actions in response to issues that cover multiple operator shifts and for errors of commission in relation to HRA as these may not be the dominant sources of human error for current water reactors, but could become dominant for advanced reactors. Research Roadmap (EPRI 3002026495) actions that support emphasizing the importance of EoCs as a source of human error for advanced reactors:

  • Develop Enhancements to Licensing Process
  • Develop Industry Recommendations for Regulatory (NRC / CNSC) Guidance on Operator Staffing

A higher level of detail for these actions can be found in the report along with Table 3-2 which summarizes the methods to assess HRA’s impact on advanced reactor safety.