RAMTAR Research: Difference between revisions
No edit summary |
m (1 revision imported) |
||
| (16 intermediate revisions by 2 users not shown) | |||
| Line 1: | Line 1: | ||
==Objective / Purpose== | ==Objective / Purpose== | ||
Given the state of development and plans for licensing / deployment of advanced reactors, RAMTAR research aims prioritize | Given the state of development and plans for licensing / deployment of advanced reactors, RAMTAR research aims to prioritize the identification and implementation of research to address gaps that support near-term licensing actions for advanced reactors. | ||
==Scope== | ==Scope== | ||
Research topics are aligned with identification and assessment of issues related to the definition, execution, and application of PRAs to the design, licensing, construction, and operation of advanced reactors. The topics listed below are limited to active or future research as part of EPRI’s Advanced Reactors research initiatives. Additional research on these topics is also being conducted by other organizations (i.e., the list is not intended to be all encompassing). Research topics include what is shown in Figure 1 on the landing page. An asterisk (*) on the sidebar denotes new material since the last update to the wiki. | |||
==Ongoing Research on Advanced Reactor Risk Assessment Methods and Tools – List of Active Project Topics== | ==Ongoing Research on Advanced Reactor Risk Assessment Methods and Tools – List of Active Project Topics== | ||
[[Risk Metrics|1 - Risk Metrics]] | |||
Risk metrics currently used for water reactors may not necessarily be applicable to advanced reactors depending on the specific advanced reactor design. There are currently a range of different solutions being investigated such as generalizing the CDF definition and/or applying the definition to become plant specific, or creating new risk metrics that are specific to plant characteristics such as mission or possible impact. | |||
<br><br> | |||
[[Passive Safety System Reliability|2 - Passive Safety System Reliability]] | |||
Passive safety systems (PSSs) will serve as a cornerstone requirement for the licensing of advanced nuclear reactor plants. Having a reliance on safety systems that are passive, that is, those that rely on natural/physical laws and require minimal or no intervention by plant operators provides a significant reduction in the probability of a serious accident. | |||
<br><br> | |||
[[External Hazards|3 - External Hazards]] | |||
Current PRA models consider external hazards such as seismic events, high winds, and external flooding. These events will continue to be considered in the risk assessment modeling for advanced reactor designs. | |||
<br><br> | |||
[[Human Reliability Analysis|4 - HRA]] | |||
Human Reliability Analysis plays a large role in identifying not only possible failures caused by plant personnel failing to follow plant procedures, but also ways in which operators can mitigate plant failures preventing an accident. Since there are no current plant procedures for advanced reactors this will present additional challenges and may even require a different methodology than what has been used for HRA applied to water reactors. | |||
<br><br> | |||
[[PRA Data|5 - Data]] | |||
This research activity will focus on identification of data and relevant characteristics necessary to support plant safety analysis and plant risk assessments that will be used for plant licensing submittals and operational decision-making. | |||
<br><br> | |||
[[Digital I&C Applications|6 - Digital I&C]] | |||
There have been substantial challenges related to obtaining efficient regulatory reviews and approvals when digital upgrades have been deployed to replace the original analog systems that interface with plant safety systems in the current fleet. To address this issue, EPRI has developed the Hazards and Consequences Analysis for Digital Systems (HAZCADS) approach. | |||
<br><br> | |||
[[Economic Risk Analysis|7 - Economic Risk Analysis]] | |||
Develop methods to measure and manage project risk (with particular focus on licensing and plant construction), assess and manage plant economic risk throughout the life-cycle (design, construction, commissioning, and operation), and develop guidance to select the most advantageous licensing approach (applicable to the US where various options exist). | |||
<br><br> | |||
[[Initiating Events|8 - Initiating Events]] | |||
This research activity focuses on realistic initiating events for advanced reactors. The objectives of this project are to investigate modifications to initiating event definitions for advanced reactors and identify any necessary technical basis to support risk-informed decision-making for new reactor designs. | |||
<br><br> | |||
[[Other Related Projects|9 - Other Related Projects]] | |||
This page is designated for new research that does not particularly fit into any other category but is highly relevant to the development of safety analysis for advanced reactors. | |||
Latest revision as of 00:10, 30 July 2026
Objective / Purpose
Given the state of development and plans for licensing / deployment of advanced reactors, RAMTAR research aims to prioritize the identification and implementation of research to address gaps that support near-term licensing actions for advanced reactors.
Scope
Research topics are aligned with identification and assessment of issues related to the definition, execution, and application of PRAs to the design, licensing, construction, and operation of advanced reactors. The topics listed below are limited to active or future research as part of EPRI’s Advanced Reactors research initiatives. Additional research on these topics is also being conducted by other organizations (i.e., the list is not intended to be all encompassing). Research topics include what is shown in Figure 1 on the landing page. An asterisk (*) on the sidebar denotes new material since the last update to the wiki.
Ongoing Research on Advanced Reactor Risk Assessment Methods and Tools – List of Active Project Topics
Risk metrics currently used for water reactors may not necessarily be applicable to advanced reactors depending on the specific advanced reactor design. There are currently a range of different solutions being investigated such as generalizing the CDF definition and/or applying the definition to become plant specific, or creating new risk metrics that are specific to plant characteristics such as mission or possible impact.
2 - Passive Safety System Reliability
Passive safety systems (PSSs) will serve as a cornerstone requirement for the licensing of advanced nuclear reactor plants. Having a reliance on safety systems that are passive, that is, those that rely on natural/physical laws and require minimal or no intervention by plant operators provides a significant reduction in the probability of a serious accident.
3 - External Hazards
Current PRA models consider external hazards such as seismic events, high winds, and external flooding. These events will continue to be considered in the risk assessment modeling for advanced reactor designs.
4 - HRA
Human Reliability Analysis plays a large role in identifying not only possible failures caused by plant personnel failing to follow plant procedures, but also ways in which operators can mitigate plant failures preventing an accident. Since there are no current plant procedures for advanced reactors this will present additional challenges and may even require a different methodology than what has been used for HRA applied to water reactors.
5 - Data
This research activity will focus on identification of data and relevant characteristics necessary to support plant safety analysis and plant risk assessments that will be used for plant licensing submittals and operational decision-making.
6 - Digital I&C
There have been substantial challenges related to obtaining efficient regulatory reviews and approvals when digital upgrades have been deployed to replace the original analog systems that interface with plant safety systems in the current fleet. To address this issue, EPRI has developed the Hazards and Consequences Analysis for Digital Systems (HAZCADS) approach.
7 - Economic Risk Analysis
Develop methods to measure and manage project risk (with particular focus on licensing and plant construction), assess and manage plant economic risk throughout the life-cycle (design, construction, commissioning, and operation), and develop guidance to select the most advantageous licensing approach (applicable to the US where various options exist).
8 - Initiating Events
This research activity focuses on realistic initiating events for advanced reactors. The objectives of this project are to investigate modifications to initiating event definitions for advanced reactors and identify any necessary technical basis to support risk-informed decision-making for new reactor designs.
9 - Other Related Projects
This page is designated for new research that does not particularly fit into any other category but is highly relevant to the development of safety analysis for advanced reactors.